Product classification

Contact us

Address: 6 West Road, Yizhuang Cultural Park, Daxing, Beijing

Telephone: +86 10 83682751

Mobile phone: +86 10 83682752

Mail:info_noelbj@126.com

Current location:
Homepage
/
/
/
RMO-TD TAP CHANGER ANALYZER & WINDING OHMMETERS

RMO-TD TAP CHANGER ANALYZER & WINDING OHMMETERS

Number of views:
1000
TheTapChangerAnalyzer&WindingOhmmeterRMO-TDisastand-aloneorPC-controlleddigitalinstrumentdesignedfordetailedanalysisofon-loadtapchangersandformeasuringresistancesofinductivetestobjectsusedintheelectricpowerindustryorsimilarindustries.Itisemployedforresistancemeasurementduringthemanufacturing,commissioningandtestingof:Transformers,On-loadtapchangers,De-energizedtapchangers,Generatorsandelectricalmotors,Highcurrentbusbarjoints,Cablesplices.TheRMO-TDisalsocapableofautomatictransformerdemagnetization.ItisrecommendedtoperformtransformerdemagnetizationafterallDCcurrenttesthavebeencompletedinordertoavoidproblemssuchaserroneousdiagnosticelectricalmeasurementsonatransformeroraninrushcurrentatthestart-upofthepowertransformerorincorrectoperationofprotectiverelaysduetomagnetizedCTcores.TheRMO-TDisalsousedtocreatetheautomaticresistance/temperaturemeasurementfortheHeatRuntesttogetherwiththeDV-Winsoftware.AnyusesoftheRMO-TDotherthantheonesmentionedaboveareconsideredimproperandwillinvalidatewarrantyclaims.
Retail price
0.0
Market price
0.0
Number of views:
1000
Product serial number
Quantity
-
+
Stock:
Product details
[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[产品参数, 参数]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]
Technical parameters
Enclosure
The Tap Changer Analyzer & Winding Ohmmeter RMO-TD is a stand-alone or PC-controlled digital instrument designed for detailed analysis of on-load tap changers and for measuring resistances of inductive test objects used in the electric power industry or similar industries. It is employed for resistance measurement during the manufacturing, commissioning and testing of:
  • Transformers,
  • On-load tap changers,
  • De-energized tap changers,
  • Generators and electrical motors,
  • High current busbar joints,
  • Cable splices.
The RMO-TD is also capable of automatic transformer demagnetization. It is recommended to perform transformer demagnetization after all DC current test have been completed in order to avoid problems such as erroneous diagnostic electrical measurements on a transformer or an inrush current at the start-up of the power transformer or incorrect operation of protective relays due to magnetized CT cores.
The RMO-TD is also used to create the automatic resistance/temperature measurement for the Heat Run test together with the DV-Win software.
Any uses of the RMO-TD other than the ones mentioned above are considered improper and will invalidate warranty claims. 
Scan the QR code to read on your phone
We could not find any corresponding parameters, please add them to the properties table

推荐新闻

News

2020

12 -20

断路器的高度可靠性是其主要的特征之-。 然而,断路器在其使用寿命期内要经 受严酷的环境考验和开断考验,当关合电流或开断故障电流时,要求断路器在毫秒级的时间内成功地履行它的职责。然后将经历几 天,几个月,甚至-年的随时操作的准备状态,在断路器漫长的运行周期内

2020

12 -10

断路器的高度可靠性是其主要的特征之-。 然而,断路器在其使用寿命期内要经 受严酷的环境考验和开断考验,当关合电流或开断故障电流时,要求断路器在毫秒级的时间内成功地履行它的职责。然后将经历几 天,几个月,甚至-年的随时操作的准备状态,在断路器漫长的运行周期内

2020

12 -10

断路器的高度可靠性是其主要的特征之-。 然而,断路器在其使用寿命期内要经 受严酷的环境考验和开断考验,当关合电流或开断故障电流时,要求断路器在毫秒级的时间内成功地履行它的职责。然后将经历几 天,几个月,甚至-年的随时操作的准备状态,在断路器漫长的运行周期内

2020

12 -10

断路器的高度可靠性是其主要的特征之-。 然而,断路器在其使用寿命期内要经 受严酷的环境考验和开断考验,当关合电流或开断故障电流时,要求断路器在毫秒级的时间内成功地履行它的职责。然后将经历几 天,几个月,甚至-年的随时操作的准备状态,在断路器漫长的运行周期内

2020

12 -10

断路器的高度可靠性是其主要的特征之-。 然而,断路器在其使用寿命期内要经 受严酷的环境考验和开断考验,当关合电流或开断故障电流时,要求断路器在毫秒级的时间内成功地履行它的职责。然后将经历几 天,几个月,甚至-年的随时操作的准备状态,在断路器漫长的运行周期内

推荐产品

Product

GIS partial discharge tester

GIS partial discharge tester

Dischargetesterhasthreekindsofmodels,whichare:1.Ultrasonicconfiguration:PD2501-A2.Theuhfconfiguration:PD2501-u3.Theultrasonic+uhfconfiguration:PD2501-A/USummary:PD2501-A/UbureauputelectricitytesterwasmadebyGermanPDcompany,thecompanyspecializedinelectricpowerequipmentresearchanddevelopmentandmanufactureofpartialdischargedetectionequipment,includingGISpartialdischargetestequipment/GIL,transformerpartialdischargetesttestequipment,generatorpartialdischargetestequipmentandcablepartialdischargetestequipmentandsoon. GISbecauseofitssmallsizeandhighreliabilityiswidelyused,buttherearealsobecauseoffreeparticles,insulationfaulthappensintheinsulatorandthedefectisaccompaniedbypartialdischargeoccurs,thuspartialdischargedetectionisoneoftheeffectivemethodsofelectricpowerequipmentinsulationconditiondiagnosis.TheAIACompactpartialdischargetesterismainlyusedinGIS,GILpartialdischargetest.Thedeviceisaportabletestingequipment,canalsobeappliedtothetransformer,thepartialdischargemeasurementofcableaccessories.Forthediagnosisofsomedefect,suchasaerosols,ultrasonictestingismuchbetterthantheusualelectricaltestoftheparticulatematterinthenewlyinstalledorafteroverhauloftheGIS,canleadtoflashflippingorbreakdown.Thisequipmentcanalsobeconnectedultra-highfrequency(UHF)sensors,frequencybandwidth:300MHZto2GHZ.Thedevicecanautomaticallyidentifytypesofsensors,automaticconversionbetweendifferenttypesofsensors.UHFUHFmethodismeasuringtechniquedevelopedinrecentyears,itadoptsthemeasurementwithintheGISinsulationhiddendangersinoperatingvoltageundertheradiationofelectromagneticwavetodeterminewhetherGISinternalpartialdischarge,UHFfrequencymethod,thebiggestadvantageiscaneffectivelyrestrainbackgroundnoise,suchascoronaproduceelectromagneticinterference.UHFsignalfrequencyishigh,strongpenetrability,aftertheinsulator,canthroughtheinsulatorwithmetalflangejointexternalarrivedinGIS,andthereforecanbeontheoutsideofthebasininsulatormeasuringUHFsignalwithintheGIS.

SF6 decomposition multicomponent analysis system

SF6 decomposition multicomponent analysis system

Productmodel:SF6-FTIR-401Origin:Germany1.TheSF6features:Sulfurhexafluoride(SF6)gas,bytwoFrenchchemistMoissanandLebeausynthesisin1900.Fromabout60s,SF6gasasexcellentinsulationandarcingmediumsuccessfullyappliedinthehighvoltageswitchanditsequipment.Today,inthefieldofhighpressure,ultra-highpressureandultra-highvoltage,SF6gasalmostbecometheonlyinsulationcircuitbreakerandGISandarcingmedium.2.ThegenerationofSF6decomposition:Whennotpure,SF6productcontaininghightoxicandlowsulfur,hydrogenfluoride,fluorideandothertoxicgases.Theproductofpartialdischarge,suchas:1)2sf6+O2->2sof2+8f(thionylfluoride)2)2sf6+O2->2sof4+4f(foursulfurylfluoride)3)theSF6-SF4+2f(sulfurtetrafluoride)4)theSF6-S+6f(S)5)2sof4so2f2+O2->2+4f(sulfurylfluoride)6)SF4+H2O-SOF2+2hf(hf)7)SOF4+H2O-SO2F2+2hf(hf)8)SOF2+H2OandSO2+2hf(sulfurdioxide) PartialdischargeofSF6decompositionwillaccelerateinsulationagingandcorrosionofmetalsurfaces,sincetheelectricalequipmentinsulationdegradationwilldirectlyleadtopartialdischarge,andevenbreakdown,shortentheservicelifeofelectricalequipment,theseriousinfluencetothesafeoperationofelectricalequipment BeforeandafterpicturesofinsulationmaterialsinSF6decompositioncorrosion  InsulationmaterialinSF6decompositiontablecompressionstrengthbeforeandaftercorrosion  3.Thepartialdischargedetectiontechnology-chemicalmethodsappliedinpartialdischargedetectionSF6decompositionmethodisusedforSF6inflatableelectricpowerequipmentfaultdiagnosis.PowersystemathomeandabroadhavebeenwidelycarriedoutpowerequipmentSF6decompositionspeciesandcontentdetection,throughthetechnologyhasalreadyfoundsomeelectricalfault,especiallyintheapplicationofpartialdischargeinGIS.Butbasedonthelimitationofthedetectiontechnology,atpresentbasedonthechemicalsensortechnologyonlycandetectSO2,H2S,severalbasicmaterialsuchasHFcontentandhasconsiderablelimitations.Forexample:SOF2;SF4;SOF4;SO2F2;S2F10;CO;COS.MaterialssuchasSiF4cannotbedetected.ButSOF4decompositionisexistenceandequipmentofadirectrelationshipbetweenthepartialdischarge.4.Infrared(FTIR)spectroscopy:Sincethe1970stothepresentinmorethan30years,Fouriertransforminfraredspectroscopy(FTIR)isdevelopingveryrapidly,asthecontinuousdevelopmentofFouriertransforminfraredspectroscopy,infraredspectrometerisinconstantdevelopment,constantlyupdated.Theemergenceofnew,advancedinfraredspectrometerattachments,makethefunctionofinfraredspectrometerattachmentsconstantlyexpanding,continuouslyimproveperformance,tomakeinfraredspectrumtechnologyismorewidelyused.Theinfraredabsorptionspectrumanalysisistoidentifycompoundsanddeterminethecommonuseofthemolecularstructureofmatter.Forasinglecomponentorcomponentsinthemixturecanquantitativeanalysis,especiallyforsomedifficulttoseparateandnoobviouscharacteristicpeaksinultraviolet,visibleareaofthesampleandquantitativeanalysisisfastandconvenienttocomplete.Infraredspectroscopyisthestudyoftheatomsinmoleculesofrelativevibration,canbesummedupinachemicalbondvibration.Differentchemicalbondsorfunctionalgroups,anditsvibrationlevelfromthegroundstatetransitiontotheenergyfortheexcitedstateisdifferent,sotoabsorbdifferentinfraredlight.Materialabsorptionofdifferentinfraredlight,willappearindifferentwavelengthabsorptionpeaks,infraredspectrumwascreated.Infraredspectrummeasurementintheareaislocatedinthe~400cm,4000cm-1-1,or2.5mmto25mmUinthesamemeasuretime,thesignal-to-noiseratiooftheFouriertransforminfraredspectrometerandobviouslyincreasethesensitivity.Takenthescanningspeed,Fouriertransforminfraredspectrometercanbemeasuredin1secondsmorethanirspectra.Takentheluminousfluxisbig,candetecttransmission,lowsampletouseavarietyofaccessories,suchasdiffuse,specularreflectionandattenuatedtotalreflection;Inadditiontodetectsamplesofdifferentforms,suchasgas,solid,liquid,thinfilmandmetalcoating.Takenthehighresolution,easytoobservethefinestructureofthegaseousmolecules.Takenthedeterminationofwidespectralrange,aslongasthelightsourcechangeaccordingly,beamsplitterandthedetectorconfiguration,youcangetthewholeintheinfraredspectrum.UwaveNumbersofhighprecision,duetothehighmonochromaticityofHe-Nelasertocontrolandmeasuretheinterferencepatternandsampling,makehighwavenumberspectrumcalculatedprecision.5.InfraredspectroscopyforSF6decompositionmulticomponentanalysis:ForeignSF6gasdecompositionresearchhasbeenconductedformanyyears,andobtainedconsiderableachievements.GermanchemicalDr.Dr.MrKurteandhisleadershipteamaftertenyearsofexplorationandresearch,combinedwithinfraredspectrumtechnologyandtheresearchofSF6decompositioncomponents,developedbasedontheinfraredspectroscopyofSF6decompositionmulticomponentanalysissystem,andequippedwithdedicateddatabasesystem.TheSF6decompositionanalysisequipmenthasbeenwidelyusedinelectricpowerengineering,hasplayedanimportantroleonpowerequipmentfaultdiagnosis.Specifictestingdataandthedetectionlimittoseethetablebelow: Theserialnumber decomposition TheminimumdetectionlimitPPMV 序号Theserialnumber decomposition TheminimumdetectionlimitPPMV1SO2108CO52HF0.59COS13SOF2510SiF424SF4211CO255SOF4312CF426SO2F2113H20107S2F102    FTIR-SF6decompositionanalysissyst

Contact us

Address: 6 West Road, Yizhuang Cultural Park, Daxing, Beijing

Scan and follow us

这是描述信息

Online Message

Username used for comment:
客户留言
Description:
1

Copyright © 2020  Beijing Noel Technology Co., Ltd   京ICP备13009632号-1   Powered by www.300.cn